Written inside a stored form, before FE: the form prints by itself once all of its variable data has arrived; the first parameter is the number of sets, the second the number of copies (EPL2 PG p. 3-77). Unlike P it does not print the label right away — calling the form starts the print. The preview keeps no printer memory, so it skips it as a form command.

Engine status: Parsed, not rendered

The engine recognises the command and skips it: it is a DEVICE setting and does not change the image on the media. Your label still parses cleanly.

Syntax

PA<p1>[,<p2>]

Example

N
q812
Q1218,24
PA1
P2

Open this example in the preview →

Open the validator →

Parameters

ParameterMeaning
p1Number of sets to print; may also arrive as variable data
p2Optional number of copies; stays with the stored form on the printer, the preview ignores it

All EPL commands

N · q · Q · A · B · LO · LW · X · P · R · S · D · I · JF · ZT · ZB · O · FS · FE · FR · FK · FI · V · ?