GS1007 — Character outside GS1 character set 82
Alphanumeric AIs (format X), such as AI (10) batch or lot number and AI (21) serial number, may only use the characters of GS1 AI encodable character set 82 (§7.11, Table 7-20): A to Z, a to z, 0 to 9 and ! " % & ' ( ) * + , - . / : ; < = > ? _. A space, #, $, @, an accented letter or any other character is not in the set, and the element string is invalid.
Element string that triggers it
(01)09521234543213(10)L#1Finding: GS1007 — (10) BATCH/LOT contains a character outside GS1 character set 82 (letters, digits and !"%&'()*+,-./:;<=>?_ only).
How to fix it
Replace the character with one from the set, for example a hyphen or an underscore instead of a space or #, or the plain letter instead of an accented one. Change the value in the system it comes from as well, so that the number scanned from the label matches the number on record.
Corrected element string
(01)09521234543213(10)L-1Related rules
GS1003 Wrong length for a fixed-length AI · GS1004 Numeric AI contains a non-digit · GS1005 Wrong check digit · GS1006 Invalid YYMMDD date · GS1008 Value longer than the AI allows
Sources
- GS1 General Specifications, Release 26.0, §7.11 (Table 7-20): the AI table and the rule quoted above.
- GS1 Application Identifiers reference