Sets the clock-indicator characters that print the Real-Time Clock's date and time inside a field.
^FCa,b,c^FC has to appear in every field that prints a date or time. In the ^FD that follows, the indicator plus a command character is replaced at print time: %d day, %m month, %y / %Y year, %H hour (24 h), %I hour (12 h), %M minute, %S second, %p AM/PM, %A / %a weekday name, %B / %b month name, %j day of the year.
The secondary and third indicators print the clocks offset with ^SO. Without Real-Time Clock hardware ^FC is ignored and the characters print as plain text. Since firmware V60.13.0.10 ^FC also works together with ^SN.
Labelixa's preview draws this command.
^XA
^FO10,25^AD^FC%,{,#
^FDDate: %d/%m/%Y %H:%M^FS
^XZPrints the current day, month, four-digit year, hour and minute from the primary clock.
| Parameter | Description | Values | Default |
|---|---|---|---|
a | primary clock indicator | ASCII | % |
b | secondary clock indicator; must differ from a and c | ASCII | — |
c | third clock indicator; must differ from a and b | ASCII | — |
Zebra ZPL II Programming Guide (P1134473-11EN Rev A), page 189. Zebra guide page →
^SL · ^SO · ^ST · ^KD · ^SN · ^FD