Serialises the field data across a batch with a start value, an increment and padding.
^SNv,n,zThis command is supported by the preview engine.
^SN1000,1,Y| Parameter | Description | Type | |
|---|---|---|---|
v | start value (may contain a number of up to 12 digits) | str | required |
n | increment (may be negative) | int | Default: 1 · Range: -9999999–9999999 |
z | keep leading zeros | enum | Default: N · Options: Y, N |
Zebra ZPL II Programming Guide (P1134473-11EN), page 341.
^PQ · ^MU · ^FN · ^DF · ^XF · ^XG · ~DG · ^DU · ^DY · ^EG · ^ID · ^SF